CLIA — US Clinical Laboratory Improvement Amendments (42 CFR Part 493)
CLIA — US Clinical Laboratory Improvement Amendments (42 CFR Part 493) — 58% covered.
6 requirements · 3 enforced · 1 designed · 0 advisory · 0 deferred.
Source: The Clinical Laboratory Improvement Amendments (CLIA), implemented at 42 CFR Part 493, set US federal quality standards for laboratory testing performed on human specimens for diagnosis, prevention or treatment. KYE Protocol™ governs the test-record and result-reporting integrity slices (Subpart J recordkeeping), the audit-trail/electronic-records slice, and the authority slice where an AI-supported algorithm contributes to a reportable result. KYE™ does not perform testing, run proficiency testing, validate analytical performance, or assess personnel competency. · License: 42 CFR Part 493 is US federal regulation in the public domain; KYE registry paraphrases each requirement's intent and cites the official identifier for mapping purposes only.
By category
| Category | Reqs | Enforced | Designed | Advisory | Deferred | Coverage |
|---|---|---|---|---|---|---|
| Test records & result-report integrity (Subpart J, 493.1105/1291) | 2 | 1 | 1 | 0 | 0 | 75% |
| Audit trail for electronic test records | 1 | 1 | 0 | 0 | 0 | 100% |
| Authority & oversight of AI-supported result generation (Subpart M) | 1 | 1 | 0 | 0 | 0 | 100% |
| Analytic systems quality & validation (Subpart K) | 1 | 0 | 0 | 0 | 0 | 0% |
| Proficiency testing & personnel competency (Subparts H, M) | 1 | 0 | 0 | 0 | 0 | 0% |
Every requirement → the KYE™ artefact that enforces it
| ID | Title | Status | KYE™ enforcement |
|---|---|---|---|
clia.493.1105-record-retention |
493.1105 — Test records and reports are retained and remain retrievable for the required period | designed | engines: internalr2_buckets: kye-evidence-archiveconstitution_refs: constitution/30-AUDIT-WORM-RETENTION.md |
clia.493.1291-report-integrity |
493.1291 — Reported test results are attributable, accurate, and any correction is traceable | enforced | audit_events: kye.evidence.decision_map.v1, kye.replay.context_seal.v1engines: internalconstitution_refs: constitution/13-RESILIENCE-LOOP.md |
clia.audit-trail |
Electronic test records carry a tamper-evident audit trail of every AI-driven change | enforced | audit_events: kye.evidence.pack.v1engines: internalworm_tables: evidence_eventsconstitution_refs: constitution/30-AUDIT-WORM-RETENTION.md |
clia.493.1445-ai-oversight |
Subpart M — A qualified, named individual authorises AI-supported result generation before it is reported | enforced | audit_events: kye.purpose.request.v1, kye.purpose.admissibility.v1engines: internalconstitution_refs: constitution/12-PURPOSE-PERMISSION.md |
clia.493-subpart-k-analytic-systems |
Subpart K — Analytic-system quality control and method validation | out-of-scope | (no enforcement cited) |
clia.493-pt-competency |
Subparts H & M — Proficiency testing and personnel competency assessment | out-of-scope | (no enforcement cited) |